CT40- EU-EN V1.7 1/13
8
Specifications
Max input voltage 600V AC/DC
Diode Test Test current 1mA max., open circuit voltage of 1.5V typical
Continuity Check Audible threshold between 15Ω and 200Ω
Display 2000 count 3 -1/2 digit LCD
Over range indication LCD displays “OL”
Polarity Minus (-) sign for negative polarity.
Low Battery Indication “BAT” symbol indicates low battery condition.
Input Impedance >7.5MΩ (VDC & VAC)
AC Response Average responding
ACV Bandwidth 50Hz to60Hz
Auto Power Off 15 minutes (approximately)
Fuse mA, µA ranges; 0.2A/250V fast acting Fuse
Batteries 9V battery and two “AAA” batteries
Operating Temperature 0°C to 40°C (32°F to 104°F)
Storage Temperature -10°C to 50°C (14°F to 122°F)
Weight 308g (10.8 oz`)
Size 162x74.5x44.0mm (6.3x2.9x1.7”),
Standards IEC61010-1 CAT III-600V Pollution degree II, CE Approved
Transmitter Specifications
Display Two red LED lamps
Alligators 17Croc clips-red*16, black*1
Cable resistance 30K Ohm max
Power 9V battery
Power current 1.8mA
Operating temperature 0°C to 40°C (32°F to 104°F)
Storage temperature –10°C to 50°C (14F to 122°F)
Receiver Specifications
Display Two digit blue LED display
Alligators 2 Croc clips-red*1, black*1
Power 9V battery
Power current 23mA
Operating temperature 0°C to 40°C (32°F to 104°F)
Storage temperature –10°C to 50°C (14°F to 122°F)
Continuity test Audible threshold between 15Ω and 1000Ω