Extech Instruments 42509 Manual de usuario Pagina 4

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 9
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 3
42509-en-GB_V1.4 12/14
4
Operating Instructions
Temperature Measurements
1. Hold the meter by its handle and point it toward the surface to be measured.
2. Pull and hold the trigger to turn the meter on and begin testing. The temperature reading, MAX
temperature reading, the ‘SCAN’ icon, the emissivity value, and the unit of measure will appear.
3. Release the Trigger and the reading will hold for approximately 7 seconds (HOLD will appear on
the LCD) after which the meter will automatically shut off. If LOCK mode is enabled, the unit will
not automatically shut off.
Note: Select the temperature units (ºF/ºC) using the switch inside the battery compartment
Dual Laser Pointer
The meter has a distance to target ratio of 12:1. The dual laser pointers
are designed to indicate the 12” distance when the laser pointers
converge. The spot size at this distance is a 1” diameter. This is the
recommended distance for most measurements. To turn the lasers
on/off:
1. Press and release the Trigger
2. While HOLD is on the display, press the laser button once to
turn the lasers on or off. The new status will appear with the next
trigger pull.
3. The laser icon will appear in the LCD when the laser function is
enabled.
4. The status of the laser will be stored in memory and will remain as
the “turn-on” condition until changed.
@12”
1”
@24”
2”
@6”
0.5”
@30cm
2.5cm
@61cm
5cm
@15cm
1.25cm
Vista de pagina 3
1 2 3 4 5 6 7 8 9

Comentarios a estos manuales

Sin comentarios