101
V4.0‐March2010
Probe
1X position 10X position
Bandwidth Up to 6 MHz (DC) Up to full bandwidth (DC)
Attenuation rate 1: 1 10: 1
Compensation range 20pf40pf
Input resistance 1M ±2 10M ±2
Input impedance 85pf115pf 14.5pf17.5pf
Input voltage 150 V DC 300 V DC
MULTIMETER
Voltage (VDC)
Input Impedance: 10M
Max. Input Voltage: 1000V (DC or AC peak-to-peak value)
Range Accuracy Resolution
400.0mv ±1.5% ±2 digit 100uV
4.000V 1mV
40.00V 10mV
400.0V
±1% ±1 digit
100mV
Voltage (VAC)
Input Impedance: 10M.
Max. Input Voltage: 750V (AC)
Frequency range: from 40Hz to 400Hz
Range Accuracy Resolution
4.000V 1mV
40.00V 10mV
400.0V
±1% ±3 digits
100mV
Direct Current (DC)
Vista de pagina 100

Comentarios a estos manuales