EX230-EU-EN-V1.2-09/10 12
Specifications
Function Range Resolution Accuracy
DC Voltage 400 mV 0.1 mV
±(0.8% reading + 6 digits)
4V 0.001V
±(0.5% reading + 2 digits)
40V 0.01V
400V 0.1V
±(0.8% reading + 2 digits)
600V 1V
AC Voltage 400 mV 0.1 mV
±(1.0% rdg + 6 digits)
4V 0.001V
40V 0.01V
400V 0.1V
600V 1V
Note: All AC voltage ranges are specified from 5% of range to 100% of range
DC Current
400 μA 0.1 μA
±(1.5% reading + 5 digits)
4000 μA 1 μA
40 mA 0.01 mA
400 mA 0.1 mA
4.000 0.001 A
±(2.5% reading + 5 digits)
10 A 0.01 A
Note: 10A for 30 sec max
AC Current
400 μA 0.1 μA
±(1.5% rdg + 5 digits)
4000 μA 1 μA
40 mA 0.01 mA
400 mA 0.1 mA
4.000 0.001 A
±(3.0% reading + 5 digits)
10 A 0.01 A
Note: 10A for 30 sec max
NOTE: Accuracy is stated at 18
o
C to 28
o
C (65
o
F to 83
o
F) and less than 75% RH.