Extech Instruments EX320 Guía de usuario Pagina 13

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 14
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 12
EX320-en-GB_V5.4 12/14
13
Specifications
Function Range Resolution Accuracy
Non-contact AC
Voltage detector
100 to 600VAC Resolution & accuracy do not apply since the meter does not
display the voltage in this mode. The lamp at the top of the
meter’s display flashes when voltage is sensed and an audible
warning will sound
DC Voltage
(V DC)
200mV 0.1mV
(0.5% reading + 2 digits)
2V 0.001V
(1.0% reading + 2 digits)
20V 0.01V
200V 0.1V
600V 1V
(1.5% reading + 2 digits)
AC Voltage
(V AC)
(50 / 60Hz)
200mV 0.1mV
(1.0% reading + 30 digits)
2V 0.001mV
(1.5% reading + 3 digits)
20V 0.01V
200V 0.1V
600V 1V
(2.0% reading + 4 digits
DC Current
(A DC)
200A 0.1A (1.0% reading + 3 digits)
2000A
1A
(1.5% reading + 3 digits)
20mA 0.01mA
200mA 0.1mA
10A 0.01A
(2.5% reading + 5 digits)
AC Current
(A AC)
(50 / 60Hz)
200A 0.1A (1.5% reading + 5 digits)
2000A
1A
(1.8% reading + 5 digits)
20mA 0.01mA
200mA 0.1mA
10A 0.01A
(3.0% reading + 7 digits)
Resistance
200 0.1 (1.2% reading + 4 digits)
2k 1
(1.2% reading + 2 digits)
20k 0.01k
200k 0.1k
2M 0.001M
20M 0.01M (2.0% reading + 3 digits)
NOTES:
Accuracy specifications consist of two elements:
(% reading) – This is the accuracy of the measurement circuit.
(+ digits) – This is the accuracy of the analog to digital converter.
Accuracy is stated at 18
o
C to 28
o
C (65
o
F to 83
o
F) and less than 75% RH.
Vista de pagina 12
1 2 ... 8 9 10 11 12 13 14

Comentarios a estos manuales

Sin comentarios