Extech Instruments: The brand of choice …trusted by the professionals.
Extech 400 Series Professional MultiMeters
15
Common Features:
Large backlit LCD display with
easy-to-read 1" digits
Type K thermometer built-in for
temperature measurements
Low current capability:
measure down to 0.1µA
Input fuse protection and
mis-connection warnings
Dims: 7.4x3.2x2"
(187x81x50mm)
Wt: 0.75lbs (342g)
Complete with CAT III test
leads, multi-position tilt stand
and velcro strap for hanging,
protective holster with test lead
holder, Type K bead wire
temperature probe (-22 to 572°F/
-30 to 300°C), and 9V battery
Models EX410/EX411
True RMS (EX411)
Manual Ranging
Models EX420/EX430
True RMS (EX430)
Autoranging
Capacitance
Frequency
Model EX470
Patented built-in non-contact
IR Thermometer design with
laser pointer
True RMS
Autoranging
Capacitance
Frequency
Relative function
NIST Certified Meters
Our in-house calibration lab certifies Extech products to NIST
standards. Meters with NIST certificates come complete with data.
Our laboratory conforms to MIL STD 45662, ISO 17025, Guide
25, and ANSI/NCSL Z540-1-1994.
EX410-NIST.......EX410 MultiMeter w/NIST Cert
EX411-NIST.......EX411 MultiMeter w/NIST Cert
EX420-NIST.......EX420 MultiMeter w/NIST Cert
EX430-NIST.......EX430 MultiMeter w/NIST Cert
EX470-NISTL*...EX470 MultiMeter w/NIST Cert
* Product certified to all functions except IR Thermometer
Accessories (see pg. 42-43)
CA500 ......Case with shoulder strap & side pockets
TP873 ......Replacement Bead wire Temperature
Probe (-22 to 572°F/-30 to 300°C)
HG500 .....Magnetic Hanging Strap
EX400 Series Professional MultiMeters
Featuring models with built-in non-contact InfraRed Thermometer
CA500: Durable case
with compartments for
meter and test leads
Patented
Functions EX410 EX411 EX420 EX430 EX470
Averaging/True RMS Averaging True RMS Averaging True RMS True RMS
Basic Accuracy (VDC) ±0.5% ±0.3% ±0.3% ±0.3% ±0.3%
AC Voltage 1mV to 750V 1mV to 750V 0.1mV to 750V 0.1mV to 750V 0.1mV to 750V
DC Voltage 0.1mV to 1000V 0.1mV to 1000V 0.1mV to 1000V 0.1mV to 1000V 0.1mV to 1000V
AC Current 0.1mA to 20A 0.1mA to 20A 0.1µA to 20A 0.1µA to 20A 0.1µA to 20A
DC Current 0.1µA to 20A 0.1µA to 20A 0.1µA to 20A 0.1µA to 20A 0.1µA to 20A
Resistance 0.1 to 20M 0.1 to 20M 0.1 to 40M 0.1 to 40M 0.1 to 40M
Capacitance 0.01nF to 100µF 0.01nF to 100µF 0.01nF to 100µF
Frequency 0.001Hz to 10MHz 0.001Hz to 10MHz 0.001Hz to 10MHz
Temperature (IR) -58 to 518°F
(-50 to 270°C)
Temperature (Type K) -4 to 1382°F -4 to 1382°F -4 to 1382°F -4 to 1382°F -4 to 1382°F
(-20 to 750°C) (-20 to 750°C) (-20 to 750°C) (-20 to 750°C) (-20 to 750°C)
Duty Cycle 0.1% to 99.9% 0.1% to 99.9% 0.1% to 99.9%
Continuity / Diode Yes Yes Yes Yes Yes
Category Rating CAT III-600V CAT III-600V CAT III-600V CAT III-600V CAT III-600V
CAT II-1000V CAT II-1000V CAT II-1000V CAT II-1000V CAT II-1000V
Warranty 1 year 1 year 1 year 3 years 3 years