CONTINUITY CHECK
WARNING: To avoid electric shock, never measure continuity on circuits or wires that have
voltage on them.
1. Set the function switch to the green position.
2. Insert the black lead banana plug into the negative COM jack.
Insert the red test lead banana plug into the positive jack.
3. Press the MODE button to indicate“ "and “ on the display
4. Touch the test probe tips to the circuit or wire you wish to check.
5. If the resistance is less than approximately 35, the audible signal will
sound. If the circuit is open, the display will indicate “OL”.
DIODE TEST
1. Set the function switch to the green position.
2. Insert the black test lead banana plug into the negative COM
jack and the red test lead banana plug into the positive V jack.
3. Press the MODE button to indicate “ “ and “Von the display.
4. Touch the test probes to the diode under test. Forward voltage
will typically indicate 0.400 to 0.700V. Reverse voltage will
indicate “OL”. Shorted devices will indicate near 0V and an
open device will indicate “OL” in both polarities.