Extech Instruments EX830 Guía de usuario, Página 1: User’s Guide1 Extech Instruments EX830 Guía de usuario, Página 2: User’s Guide2 Extech Instruments EX830 Guía de usuario, Página 3: Introduction3 Extech Instruments EX830 Guía de usuario, Página 4: CAUTIONS4 Extech Instruments EX830 Guía de usuario, Página 5: Description5 Extech Instruments EX830 Guía de usuario, Página 6: Operation6 Extech Instruments EX830 Guía de usuario, Página 7: Resistance Measurements7 Extech Instruments EX830 Guía de usuario, Página 8: Continuity Measurements8 Extech Instruments EX830 Guía de usuario, Página 9: Continuity Measurements9 Extech Instruments EX830 Guía de usuario, Página 10: Units Switch10 Extech Instruments EX830 Guía de usuario, Página 11: Maintenance11 Extech Instruments EX830 Guía de usuario, Página 12: Specifications12 Extech Instruments EX830 Guía de usuario, Página 13: Specifications13 Extech Instruments EX830 Guía de usuario, Página 14: WARRANTY/DISCLAIMER14 Extech Instruments EX830 Guía de usuario, Página 15: Shop online at omega.com15
EX830-EU-EN-V5.2-3/12
6

Resistance Measurements

Note: Remove power before making resistance measurements
1.
Insert the black test lead into the negative
COM
terminal and the red test lead
into the
Ω
positive terminal.
2.
Set the function switch to the
Ω
position.
3.
Touch the test probe tips across the circuit or component under test.
4.
Read the resistance on the LCD display.

Capacitance Measurements

WARNING:
To avoid electric shock, discharge the capacitor under test before
measuring. If “
dISC
” appears in the display, remove and discharge
the capacitor.
1.
Set the function switch to the
capacitance position.
2.
Insert the black test lead banana plug into the negative
COM
jack
and the red test lead banana plug into the
CAP
positive jack.
3.
Press MODE to zero any stray capacitance.
4.
Touch the test probe tips across the part under test.
5.
Read the capacitance value in the display.
6.
The display will indicate the proper decimal point and value.
Note: For very large values of capacitance measurement time can be several minutes
before the final reading stabilizes.

Frequency Measurements

1.
Set the function switch to the V Hz Position.
2.
Press and hold the MODE button to select the Frequency (Hz)
function. “k Hz” will appear in the display.
3.
Insert the black test lead banana plug into the negative COM jack
and the red test lead banana plug into the Hz positive jack.
4.
Touch the test probe tips across the part under test.
5.
Read the Frequency value on the display.
6.
The display will indicate the proper decimal point and value.
7.
Press and hold the MODE button again to return to the voltage mode
Ù
CAP
Hz

Archivo PDF · ·

Imprimir

Imprimir documento

Compartiendo

Preguntas sobre Extech Instruments EX830

Todavía no hay preguntas sobre este manual. Haga la primera.

Hacer una pregunta

Respondemos con el manual e indicamos la página. La pregunta se publica en el sitio después de revisarla.

Todas las preguntas y respuestas ›

Productos y manuales relacionados para Multímetros Extech Instruments EX830