4 5
insulation and ground tester
electrical tool
EX-096
380926 2000A AC/DC CLAMP METER
Full range multimeter functions with high
resolution to 0.1μA/0.1mV and CAT IV-600V safety
rating.
• Current measurements to 2000A through the
clamp and 400mA via test leads
• Rugged 2” (50mm) jaws accommodate one
2000MCM or two 500MCM cables
• Features include DCA push button zero, relative
measurements and data hold
• Heavy duty ABS case with built-in stand and thumb
control function switch
• Complete with test leads and 9V battery
Specifications RANGE
Averaging/True RMS True RMS
Display Counts 5,000
Jaw Size 2”
AC/DC Voltage 1mV to 1000V
AC Current/DC Current 0.1 to 2000A
Basic ACA Accuracy ±2%
Resistance 0.1Ωto40MΩ
Capacitance 10pF to 50μF
Frequency 0.001Hz to 100kHz
Continuity / Diode Yes
Category Rating CAT IV-600V
EX-066
380396 DIGITAL HIGH VOLTAGE INSULATION TESTER
Wide range measurement up to 5kV
Withinsulationresistanceto60GΩ.
• Large 6000 count display with bar graph and
backlight
• Polarization index measurement (PI)
• Dielectric absorption ratio measurement (DAR)
• Max./Min., peak and relative functions
• 1 to 15 minute timer function for IR measurements
• Indication of output voltage and discharge voltage
• Auto-discharge function and voltage output
warning function
• Complete with test leads, 8 x C batteries, AC
adaptor, and heavy duty carrying case
Specifications RANGE
Test Voltage 500V/1000V/2500V/5000V
Insulation Resistance 6MΩ,60MΩ,600MΩ,6GΩ,60GΩ
Accuracy ±2.5%
AC/DC Voltage 0 to 600V (1%)
Resistance 0to600Ω(1.5%)
Continuity 50Ω
EX-122
GRT300 4-WIRE EARTH GROUND RESISTANCE
TESTER
Includes all hard ware necessary to measure earth
ground.
• 4-wire, 3-wire, and 2-wire testing
• Large dual line LCD
• Autoranging
• Automatic I (current) spike check
• Automatic P (potential) spike check
• Test hold function for easy operation
• Automatic zero adjustment
• AC earth voltage
• Data hold and auto power off
• Over range and low battery indication
Specifications range
Earth Ground Resistance Ranges 2Ω/20Ω/200Ω/2000Ω
Basic Accuracy ±(2%rdg+3d)
Resolution 0.01Ω/0.1Ω/1Ω/0.01kΩ
Test Current / Frequency <2mA / 820Hz
AC Earth Voltage / Frequency 0 to 300VAC / 40 to 500Hz
Accuracy ±(2%rdg+3d)
Power supply Eight 1.5V ‘AA’ Batteries
Dimensions 9.8 x 7.8 x 4.3” (250 x 190 x 110mm)
Weight 3.15lbs (1430g) (batteries included)
Complete with test leads with alligator clips, 4 auxiliary earth bars,
hard carrying case, and eight 1.5V AA batteries
Complete with Accessories
for insulation Measurements
Large jaw size for high
current measurements
www.kawanlamaonline.com
For Professional use