Applications
TelephoneElectricalGroundRods
1. Removeanyprotectivecoveringfromthegroundconductor
2. TurnthemeterswitchtotheOhmfunction.
3. Oncethestartupcalibrationprocedureiscompletedclampontoanelectrodeorground
rod.
4. Allowseveralsecondsforthemetertosettleandthennotethereading.
CellularTransmissionTowers
WARNING:Useextremecarewhenmakingmeasurementsaroundtransmissiontowers;High
Voltagemaybepresent.
Thegroundconductorshouldbelocatedatthebaseofthetower,butyourconfigurationmay
bedifferent.
1. Locatethegroundconductor
2. Clamparoundthegroundconductor.Youshouldplacetheclampbeforeanysplices,bonds
orothersplitsinthegroundsystem.
3. Readthemeasuredreading.
Transmission
Tower
Primary
Ground Conductor
Branch
Ground Conductors
Cement Pad