ApplicationSpecificInformation
MeasuringPowerToolsandSmallAppliances
Forsmallappliances,connecttheGREEN(EARTH)leadtoconductorsandtheRED(LINE)leadto
insulatingmaterial.
Forsingleordoubleinsulatedpowertools,oneleadshouldbeconnectedtothedevice’schuck,
blade,etc.andtheotherleadtooneoftheACpowercordconductors(testbothconductorsin
turn).Refertothepowertoolapplicationdiagrambelow.
ACMotorTest
Disconnectthemotorfromthelineby:
a. Disconnectingthewiresfromthemotor
terminalsor,
b. Openingthemainswitch
Ifthemainswitchisopened,andthemotorhasamotorstarter,thenthestartermustbeheldin
the ON position. With the main switch opened, the measured resistance will include the
resistanceofthemotorwireandalloftheothercomponentsbetweenthemotorandthemain
switch. If a weakness is indicated, the motor and other components should be checked
individually. If the motor is disconnected at the motor terminals, connect the RED lead to
the
groundedmotorhousingandtheGREENleadtooneofthemotorleads.
AC
Plug
For 2 or 3 prong plugs, connect the
RED lead to one conductor at a time
Connect the GREEN
lead to the chuck
Connect RED lead
to grounded housing
Connect GREEN lead
to the motor leads